1-20 ton gas/oil fired boiler
Capacity: 1-20 ton/h
Pressure: 0.7-2 Mpa
Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.
Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.
7-70 MW gas/oil fired hot water boiler
Capacity: 7-70 MW
Pressure: 1.0-1.6 Mpa
Fuel: Nature gas, coke oven gas, blast furnace gas, carbon black off-gas, biogas, methanol, LPG, diesel, heavy oil, light oil, crude oil, etc.
Industries: Heat supplying, hospital, colleges and universities.
2.8-29mw coal fired boiler
Capacity: 2.8-29mw
Pressure: 1.0-1.25 Mpa
Fuel: Bituminous coal, lean coal, anthracite
Industries: Heating, hotels, schools, hospitals
horizontal thermal fluid heater
Capacity: 700 - 14000 kw
Pressure: 0.8 - 1.0 Mpa
Fuel: natural gas, coke oven gas, bio-gas,liquid propane gas, diesel, heavy oil, light oil, crude oil
Industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industries
1-20 ton biomass fired boiler
Capacity: 1-20 ton/h
Pressure: 0.7-2.5 Mpa
Fuel: Biomass particles
Industries: Heating, chemical, food, tobacco, textile, printing and dyeing, feed, medicine, building material, wine, rubber, hospital

Flue Gas - Science Direct
Flue gases are a mixture of combustion products including water vapor, carbon The typical furnace outlet temperature of flue gases is usually around 1200 °C

Flue Gas - Science Direct
Flue gas from the 300 GW of U.S. pulverized coal-fired boiler capacity . of flue gas at temperatures of 250350°F. From an inlet manifold, the dirty flue gas , with

recovery of water from boiler flue gas - OSTI.gov
1 Jan 2006 boiler flue gas and the magnitude of the heat rate improvements which could be . Temporal Variation of Inlet Flue Gas Water Vapor Volume.

Protecting Boilers Against Flue Gas Condensation | 2017-08-14
14 Aug 2017 A thermodynamic balance between the boiler and distribution system is achieved, and the boiler inlet temperature is high enough to avoid flue gas condensation.

Module 106: Natural gas boiler flue gas recirculation to reduce NOx
Module 106: Natural gas boiler flue gas recirculation to reduce NOx emissions . includes condensate drainage points in the duct adjacent to the burner inlet .

Flue gas system.pdf
MULTI FUEL CFB BOILER SIMULATOR ID fan inlet damper . . Part of the flue gases is possible fed back to the furnace for temperature control in furnace .

Flue - gas stack - Wikipedia
A flue - gas stack is a type of chimney, a vertical pipe, channel or similar structure through which combustion product gases called flue gases are exhausted to the outside air. Flue gases are produced when coal, oil, natural gas, wood or any other fuel is combusted in an industrial furnace , as nitrogen and excess oxygen remaining from the intake combustion air.

The flue gas inlet temperature and outlet temperature (both solid
The flue gases exiting a classic boiler are the hotter the higher the boiler load is. Conversely, the flue gases exiting the HRSG maintain the same temperature

Flue Gas Dilution Fans - Airflow Developments
Airflow offer a tried and tested range of ErP 2013/2015 compliant flue gas which enable combustion products from gas fired boilers and water heaters to be Based on efficient and quiet double inlet centrifugal fans they are capable of

Condensing flue gas heat exchanger - Hoval
With this flue gas heat exchanger you obtain the highest energy efficiency. For all conventional In addition, a significant improvement in boiler efficiency is noted, due the ability of full flue gas due to multi-position flue gas inlet and flue gas

Avoiding Boiler Chimney Corrosion - Forbes Marshall
Exhaust gas quality plays an important role in corrosion of the boiler chimney. boiler and the chimney, the flue gas temperature at the outlet might fall below

Understanding Boiler Stack Losses - Forbes Marshall
The best way to tackle the situation is monitoring flue gas temperature just at the boiler outlet and cleaning the tubes when it goes beyond acceptable limits.

Study of flue - gas temperature difference in supercritical - IOPscience
FGT at furnace outlet . . 1029. 994. Flue gas exhaust temperature. . 127. 121. Boiler efficiency. %. 93.07. 93.29. Table 2. Main design coal for the boiler . Item.

Recovery of water from boiler flue gas - Lehigh Preserve
8 Jan 2008 New methods are needed to recover water and heat from boiler flue gas in order to reduce overall plant water intake , increase efficiency, and

Power 101: Flue Gas Heat Recovery in Power Plants, Part I
4 Jan 2010 The temperature of the flue gas leaving the boiler is commonly reduced in an range between the APH flue gas inlet and outlet temperatures.

maximum energy gain from flue gases - Scheuch GmbH
to 50 % of boiler output can be recovered from the exhaust gas . Flue gas inlet . Condenser for using latent heat. Process water for periodical cleaning.