1-20 ton gas/oil fired boiler
Capacity: 1-20 ton/h
Pressure: 0.7-2 Mpa
Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.
Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.
7-70 MW gas/oil fired hot water boiler
Capacity: 7-70 MW
Pressure: 1.0-1.6 Mpa
Fuel: Nature gas, coke oven gas, blast furnace gas, carbon black off-gas, biogas, methanol, LPG, diesel, heavy oil, light oil, crude oil, etc.
Industries: Heat supplying, hospital, colleges and universities.
2.8-29mw coal fired boiler
Capacity: 2.8-29mw
Pressure: 1.0-1.25 Mpa
Fuel: Bituminous coal, lean coal, anthracite
Industries: Heating, hotels, schools, hospitals
horizontal thermal fluid heater
Capacity: 700 - 14000 kw
Pressure: 0.8 - 1.0 Mpa
Fuel: natural gas, coke oven gas, bio-gas,liquid propane gas, diesel, heavy oil, light oil, crude oil
Industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industries
1-20 ton biomass fired boiler
Capacity: 1-20 ton/h
Pressure: 0.7-2.5 Mpa
Fuel: Biomass particles
Industries: Heating, chemical, food, tobacco, textile, printing and dyeing, feed, medicine, building material, wine, rubber, hospital

12 Ways To Avoid Boiler Tube Corrosion - Boilersmith
4 May 2010 place along the top of the tubes on the outside , and it is our belief that this . Corrosion on the fire side of boiler tubes is caused by moisture

A Review of the Common Causes of Boiler - Semantic Scholar
The fire - tube boilers covered a steam production range of 1-20 t/hr at . Corrosion occurs externally where damp conditions are allowed to remain over the

Corrosion Control in Off-Line Steam Boilers - FMLink
Dissolved oxygen can cause serious corrosion damage to the carbon steel Also, clean boiler tubes are more susceptible to oxygen corrosion than scaled tubes . be added and the boiler water circulated by means of an external pump or by Precautions must be taken to prevent the entry of moisture during storage ,

Description of Boiler Failures - METSERVE International
Causes : Tube damage occurs due to the combination of thermal fatigue and corrosion . Corrosion fatigue is influenced by boiler design, water chemistry, boiler water oxygen content and boiler operation. A combination of these effects leads to the breakdown of the protective magnetite on the ID surface of the boiler tube .

the problem of steam boiler corrosion - Jstor
tures in the entire absence of moisture . 2. The presence of cause corrosion even in the absence of carbon dioxide or other acids. In natural water . external to the metal, although the damage done to the metal by the latter and the . of carbon dioxide before the water enters the boilers , the boiler tubes may be severely

Corrosion in boilers - Lenntech
Corrosion is a relevant problem caused by water in boilers . They usually start at internal tube surfaces and are most often circumferential on the tube .

Leakage Failure Analysis in a Power Plant Boiler - Core
Seriously study the boiler "Four Tubes " leakage causes and corresponding preventive feed water deaerator, control water content ; control the coal economizer tubes of water Tube exerted, external medium to long time corrosion on a pipe.

Furnace -Wall Corrosion in Refuse-Fired Boilers
Corrosion problems occur on supports, superheater, and furnace water wall tubing. Corrosion of furnace -wall panel tubes with fireside . (b) Sodium is more abundant in outer portions of the deposit. Corrosion in the RDF-fired unit appears to be caused . scopic and become moist during out-of-service periods. The pH

Boiler Efficiency and Steam Quality: The Challenge of Creating
Since steam is produced by the rapid boiling of water in high-heat flux boilers , . In some cases, the external water level indicator shows the water level as that high total dissolved solids in boiler water increase tube corrosion and/or fouling.

water tube boiler characteristics and terminology - AXA XL
This section introduces large and highly specialized water tube boilers , such as .. external corrosion caused by condensed moisture under similar conditions.

(DOC) Boiler Operation & Maintenance | Susovan Sensharma
A tool should preferably be passed through the tube lengths specially those in . Water content of a boiler is a useful storage of heat and a boiler having large water .. when the units are not in service, as steam may cause external corrosion .

Chapter 11 Preboiler And Boiler Corrosion Control - Suez Water
It is estimated that problems due to boiler system corrosion cost industry billions of dollars per year. . Water flows into the deposit and heat applied to the tube causes the water to .. The outer layer is thinner, porous, and loose in structure.

Introduction to Boiler water and Steam raising
Water tube boilers - Products of combustion pass around the tubes containing water. the quality of this source prior to its use as boiler feed water, external to the operating boiler itself. . Elevated temperature in itself does not cause corrosion . .. As these bubbles burst, the subsequent moisture is entrained with the steam.

Studies on the Failure of Economizer Tubes Involving Acid Dew - Ijser
Boiler tube failure is a major cause of concern to plant engineers as it leads tubes [5], premature water side corrosion of furnace wall tubes in a high The external corrosion is a function of sulfur and moisture in the economizer, tube metal.

The soot and scale problems - Heating
will also cause corrosion . Scale is a hard The cause of scale will be extensively discussed in lecture 15. Soot high moisture content and too much excess air. d) Erratic Figure 1 shows a water or superheater tube with soot at the outside at the outside . Fire tube boilers are usually smaller (1 to 25 t/h) and mostly in the.

Inspection of Fired Boilers and Heaters
Fireside Face of Tube Severely Corroded . 13 Localized Tube Wall Loss Caused by Caustic Gouging . . . . . . . . . . . . . . . . . . . . 20 .. surface. 3.25 fire tube boiler : A shell and tube heat exchanger in .. external bank or banks of tubes connecting the two ends of .. of Tubes. After Exposure to Moisture and Corrosive Deposits.

labour department hong kong - HKU Libraries
the fire -box and external shell of the Cochran boiler are hemispherical in (4) They are prone to corrosion on the outside . (5) A comparatively .. If steam entered the Bourdon tube direct it would cause it to expand or lengthen and the Hydrogen on complete combustion produces moisture , while sulphur forms sulphur

Lay-up of Cooling Towers and Boilers with Volatile Corrosion
20 Jan 2017 The VCIs are compatible and safe to use with boiler water and They do not protect against corrosion directly but rely on eliminating moisture and thus They can cause significant gunk balls in the equipment and are difficult to dispose. pounds per hour water tube boiler and a 1000 HP fire tube boiler .