1-20 ton gas/oil fired boiler
Capacity: 1-20 ton/h
Pressure: 0.7-2 Mpa
Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.
Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.
7-70 MW gas/oil fired hot water boiler
Capacity: 7-70 MW
Pressure: 1.0-1.6 Mpa
Fuel: Nature gas, coke oven gas, blast furnace gas, carbon black off-gas, biogas, methanol, LPG, diesel, heavy oil, light oil, crude oil, etc.
Industries: Heat supplying, hospital, colleges and universities.
2.8-29mw coal fired boiler
Capacity: 2.8-29mw
Pressure: 1.0-1.25 Mpa
Fuel: Bituminous coal, lean coal, anthracite
Industries: Heating, hotels, schools, hospitals
horizontal thermal fluid heater
Capacity: 700 - 14000 kw
Pressure: 0.8 - 1.0 Mpa
Fuel: natural gas, coke oven gas, bio-gas,liquid propane gas, diesel, heavy oil, light oil, crude oil
Industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industries
1-20 ton biomass fired boiler
Capacity: 1-20 ton/h
Pressure: 0.7-2.5 Mpa
Fuel: Biomass particles
Industries: Heating, chemical, food, tobacco, textile, printing and dyeing, feed, medicine, building material, wine, rubber, hospital

Modeling of fire - tube boilers - Hal
19 Feb 2013 In fire - tube boilers , the flue gas passes inside boiler tubes , and heat is transferred to water on the shell side.

Flue Gas Velocity of Pulverized coal fired Boiler ? - ResearchGate
To get the Reynolds Number i do need to find out the flue gas velocity . The calculation is for Pulverized coal fired supercritical boiler of 1650 t/h capacity. exchanging section thats mean apart from obstracals of tube and hanger tubes etc.

How Important is Surface Area" .?
Fire - tube and water- tube boilers are widely used in other factors as well, including gas velocity , the size of In fire - tube boilers (Figure 1), flue gas flows inside

Boilers , contd water velocity 15 casing 55 chimney (heat) loss: see
emissions: see Emissions from boiler plant fire tubes 62 flow water temperature 16, 50 flue gas (heat) loss: see stack loss flue hood 29, 61, 65 flues : see Flues .

Flue gas recirculation system for fire tube boilers and burner therefor
21 Apr 1987 A flue gas recirculation system for fire tube boilers includes a duct to take advantage of the flue gas velocities traveling upwardly in stack 16.

Fire - tube boiler - Wikipedia
A fire - tube boiler is a type of boiler in which hot gases pass from a fire through one or (many) boilers with one or two large flues , fire - tube boilers with many small tubes , and high-pressure water- tube boilers . .. pump(s) and a secondary piping loop with pump(s); and either a variable speed controlled pump to transfer

Chimney Sizing - Engineering ToolBox
Calculate chimney draft and required chimney area. The velocity of air and flue gas in a smaller furnace should not exceed 2 m/s. Design velocities of larger

Oil and gas | PJ-Automation & PJ-Engineering
From the front part of the boiler the flue gas is directed through the fire tubes into the flue gas duct attached to the back end of the boiler . The basis for the design is that the heat load of the furnace and the velocity of flue gas in the convection part are low. Also the pressure loss of the boiler is low.

Energy Engineering Test - Sanfoundry
5 Apr 2018 Which of the given boilers velocity of flue gases is greater than velocity of sound? a) Benson d) Combustion gases are circulated through tubes with supersonic speed . View Answer boiler ? a) Safety against fire causes

boiler efficiency guide - Cleaver-Brooks
not need high maintenance, boiler tube , add-on devices if the boiler is designed for optimum flue gas velocities in the buy-out burner will fire the unit, however.

Efficiency studies of combination tube boilers - ScienceDirect
wind velocity , m/s Although the fire tube boilers possess a steam reservoir of large size, they are less efficient. Ghritlahre and Singh [25] have studied the dry flue gas losses and efficiency of an Artificial Fluidized Bed Combustion (AFBC)

Fire Tube - an overview | ScienceDirect Topics
50 kg/s. In addition to steam generation, a large number of fire tube boilers are used to heat hot water for residential or commercial use. Hot flue gas transfers heat through tubes to the water. Saturated steam . u = velocity in tubes , m/s or ft/ s.

A Discussion of Boiler Design - Laars
gradually displaced the vertical fire tube boiler which at one time had been Table of water velocities through various types of boilers , compared to normal flow in piping . condensate on the cold surfaces exposed to the flue products. This is

Shell Boilers - Spirax Sarco
Shell boilers may also be referred to as ' fire tube ' or 'smoke tube ' boilers because 5 - 9 m long through which passed two large-bore furnace tubes called flues . This low velocity meant that, even with water containing high concentrations of

Understanding Boiler Stack Losses - Forbes Marshall
The best way to tackle the situation is monitoring flue gas temperature just at the boiler outlet and cleaning the tubes when it goes beyond acceptable limits.

Technical Book Fire tube steam boilers SG
STEAM-MATIC SG fire tube steam boilers produce saturated or . Higher speed of the flue gases even with boiler running at low rate. 2. COMPETITIVE

Chimneys and Draft
This difference will increase with the velocity of the gases. The breeching, the boiler damper, the baffles and the tubes , and the coal on the grates all stack or flue may be 0.5 inch, while in the furnace directly over the fire it may not be over,

(a) Dry Saturated Steam At A Temperature Of 180ºC - Chegg
fire tube boiler from the cooling of 50 000 kg h1 of flue gases from a pressurised combustion The average flue gas velocity through the tubes to maintain the