1-20 ton gas/oil fired boiler
Capacity: 1-20 ton/h
Pressure: 0.7-2 Mpa
Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.
Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.
7-70 MW gas/oil fired hot water boiler
Capacity: 7-70 MW
Pressure: 1.0-1.6 Mpa
Fuel: Nature gas, coke oven gas, blast furnace gas, carbon black off-gas, biogas, methanol, LPG, diesel, heavy oil, light oil, crude oil, etc.
Industries: Heat supplying, hospital, colleges and universities.
2.8-29mw coal fired boiler
Capacity: 2.8-29mw
Pressure: 1.0-1.25 Mpa
Fuel: Bituminous coal, lean coal, anthracite
Industries: Heating, hotels, schools, hospitals
horizontal thermal fluid heater
Capacity: 700 - 14000 kw
Pressure: 0.8 - 1.0 Mpa
Fuel: natural gas, coke oven gas, bio-gas,liquid propane gas, diesel, heavy oil, light oil, crude oil
Industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industries
1-20 ton biomass fired boiler
Capacity: 1-20 ton/h
Pressure: 0.7-2.5 Mpa
Fuel: Biomass particles
Industries: Heating, chemical, food, tobacco, textile, printing and dyeing, feed, medicine, building material, wine, rubber, hospital

Pressure Steam - an overview | ScienceDirect Topics
High - pressure units are smaller for a given capacity , and the initial cost is only slightly 16.7(f)) is 90 bar compared to 99/ 100 bar for the other two optimised designs. Main steam pressure control: Fuel demand of a tangential tilt boiler . .. the pipe size whose factor is equal to or smaller than the result of step (11) above .

High pressure boilers (1) - SlideShare
2 Feb 2016 1 HIGH PRESSURE BOILERS Modern Steam Power plant Sneh Patel boilers ( 6 o Evaporative of water above critical pressure of steam. o Heating .. drum boiler may be as high as 100 bar and steaming capacity upto 27000 kg/h. of a strong glass tube whose ends pass through stuffing boxes consists

Marine steam boilers
Important marine steam boilers information for marine-engineers using in the exhaust gas duct after the boiler , used to heat the steam above the saturation temperature. At high pressure , providing a more positive means of maintaining the V2M8 marine steam boilers V2M8 marine steam boiler whose major design

High Pressure Boilers : Features and Advantages ~ ME Mechanical
27 Oct 2016 High - Pressure Boilers operates above 80 bars pressure; Features of temperature of heat addition and evaporation capacity if the boiler .

Boiler Fittings and Mountings - Spirax Sarco
Its function is to protect the boiler shell from over pressure and subsequent explosion. must be at least equal to the 'from and at 100 °C' capacity of the boiler . will always be higher than the actual maximum evaporative boiler capacity . . be left open until a pressure of about 0.5 bar is showing on the pressure gauge.

Air Conditioning Energy Consumption and Environmental Quality - Google Books Result

Steam and Condensate - What is Steam and the properties of Steam
At atmospheric pressure (0 bar g), water boils at 100 °C, and 419 kJ of of 100 °C . It is from these figures that the value for the specific heat capacity of water If the steam is restrained from leaving the boiler , and the heat input rate is . Flash steam occurs whenever water at high pressure (and a temperature higher than the

BOILERS | Energy-Models.com
F & A means the amount of steam generated from water at 100 o C to saturated steam at 100 o C. IBR Steam Boilers means any closed vessel exceeding 22.75 liters in capacity and passes through such pipes exceeds 3.5 kg/cm 2 above atmospheric pressure .. This type of blow down is common in high - pressure boilers .

Safety valve - Wikipedia
A safety valve is a valve that acts as a fail-safe. An example of safety valve is a pressure relief valve (PRV), which automatically releases a substance from a boiler , pressure vessel, or other system, when the pressure . This was unadjustable and released at a higher pressure , intended as a guarantee of safety. When used

Superheated water - Wikipedia
Superheated water is liquid water under pressure at temperatures between the usual boiling point, 100 °C (212 Specific heat capacity at constant pressure also increases with temperature, from 4.187 kJ/kg at 25 °C to 8.138 Water has a high relative permittivity of about 80 at room temperature; because polarity shifts are

DNV Ship rules Pt.4 Ch.7 - Boilers , Pressure Vessels, Thermal-Oil
Rules for Ships / High Speed, Light Craft and Naval Surface Craft, January 2003 fluids with pressure above 40 bar . fluids, fluids with flashpoint below 100 °C or fluids with temperature above 220°C may be graded as class volumetric capacity mm (1.97 in) and whose neck height does not exceed 50 mm. (1.97 in).

Industrial Systems / Process steam - Schmid energy solutions
Steam boilers are used particularly in industrial processes. serves to produce water vapour of higher than atmospheric pressure or hot water with temperatures above 100 Low pressure 3-pass boiler with an operating pressure of 5-8 bar and a capacity of 0.4-2 t/h High pressure 2-pass boiler with 15-17 bar and 2-7 t/ h.

Requirements for Boiler and Pressure Vessel Manufacture - AQSIQ
The Requirements apply to all boiler and pressure vessel product The Lifting capacity at main workshops should meet the manufacturing demand of boiler are consigned outside, the above requirements for examiners holding RT II and UT II . Super- high pressure vessel manufacturer in level A1 licensing manufacturer.

Report from the Select Committee on Steam-navigation to India: - Google Books Result

Chapter SPS 341 (EXCERPTS FROM BOILER , PRESSURE
pressure , high temperature water boilers and to parts and appur- tenances thereto and shall pressure of more than 15 psig ( 100 kPa) for use external to itself PG67.2 The safety valve or safety relief valve capacity for each boiler 22 The poweractuated pressure relieving valve is one whose movements to open or

High - Pressure Test Facility - 25 Years of Operation - Siemens
A high - pressure test facility which is installed in an accred- ited laboratory at BENSON boilers and raw-gas heat-recovery steam gen- erators. The test rig's . pressures up to 100 bar . have an influence on feedwater pump capacity , but knowl- edge of this parameter is also essential, above all, for cal- culating flow