1-20 ton gas/oil fired boiler
Capacity: 1-20 ton/h
Pressure: 0.7-2 Mpa
Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.
Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.
7-70 MW gas/oil fired hot water boiler
Capacity: 7-70 MW
Pressure: 1.0-1.6 Mpa
Fuel: Nature gas, coke oven gas, blast furnace gas, carbon black off-gas, biogas, methanol, LPG, diesel, heavy oil, light oil, crude oil, etc.
Industries: Heat supplying, hospital, colleges and universities.
2.8-29mw coal fired boiler
Capacity: 2.8-29mw
Pressure: 1.0-1.25 Mpa
Fuel: Bituminous coal, lean coal, anthracite
Industries: Heating, hotels, schools, hospitals
horizontal thermal fluid heater
Capacity: 700 - 14000 kw
Pressure: 0.8 - 1.0 Mpa
Fuel: natural gas, coke oven gas, bio-gas,liquid propane gas, diesel, heavy oil, light oil, crude oil
Industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industries
1-20 ton biomass fired boiler
Capacity: 1-20 ton/h
Pressure: 0.7-2.5 Mpa
Fuel: Biomass particles
Industries: Heating, chemical, food, tobacco, textile, printing and dyeing, feed, medicine, building material, wine, rubber, hospital

USING BOILER FLUE TEMPERATURE TO CALCULATE
USING BOILER FLUE TEMPERATURE TO CALCULATE. IMPROVED BOILER EFFICIENCY DUE TO DESCALING. Introduction. A steam boiler with any amount

5 Factors Killing Your Industrial Boiler Efficiency & What to Do About It
2 Dec 2016 If the flue gas temperature is high, it suggests the heat created by the boiler isn't being effectively used to generate steam . In other words, a high

Determination of Industrial Boiler Temperature Profile for Oil and
Industrial boilers firing oil or gas with heat input of more than 100 MMBtu/hr are includes boiler furnace exit temperature of flue gases leaving the furnace

epsrc thermal management of industrial processes - research.ncl.ac
Another reason is that it is difficult to utilise the heat at low temperatures (i.e. approximately 150°C which is the average flue gas temperature). Nevertheless, industrial condensing boilers (condensers) are designed to recover this latent heat from the flue gases.

Total System Efficiency - An Introduction to Condensing Boilers
In the past, the industry standard for hot water boilers was based on a Figure 3: Example of flue gas condensation temperature based on the hot water return

Technical advice on boiler combustion control - Reliable Plant
The U.S. Department of Energy's Industrial Technologies Program recently The flue - gas temperature of a typical boiler could be anywhere in the range of 300

Flue Gas - an overview | ScienceDirect Topics
When high- temperature flue gas enters the convection chamber, its velocity is of an industrial ethylene cracking furnace, Chem Eng J 286:436446, 2016.

Firing rate versus flue temperature Heating Help: The Wall
A modulating burner keeps a boiler hotter during the off cycle rather than letting the water or steam temperature drop. Something tells me that a boiler at 180

Fuels Exhaust Temperatures - Engineering ToolBox
Exhaust and outlet temperatures for some common fuels - natural gas , liquefied petroleum, diesel and more.

4 Factors that Impact Energy Loss in Boilers Honiron Manufacturing
This is normally evident in a rise in flue gas temperature , indicating heat loss during 4) Steam Losses Energy can be lost if steam or hot water is allowed to

Investigation of exhaust gas temperature distribution within a
5 Jun 2016 Keywords: Exhaust gas temperature measurement; Grate boiler ; to produce steam or hot water that is used by district heating companies.

Utility flows should be measured accurately - Forbes Marshall
Every 20 degC deviation from optimum flue gas temperatures increases the fuel consumption by 1% The table below presents the minimum parameters that

Protecting Boilers Against Flue Gas Condensation | 2017-08-14
14 Aug 2017 The North American hydronics industry struggled with this issue for several years This temperature is low enough to cause sustained flue gas

Flue Gas Economisers | JBC
Flue Gas Economisers Typical boiler high fire exit flue gas temperatures are hot water returning back it may be possible to shut off the hotwell steam heating,

Boiler Flue Gas Temperature Problem - Steam Forum and Power Forum
At Gas Air Heater GAH outlet flue gas path, there are thermocouples which read flue gas temperature called Back End Temperature .

Stack Losses for Natural Gas | Natural Resources Canada
27 Aug 2018 1 lb of steam = 1000 Btu is an approximation sufficiently accurate for this It is important that measurements of flue gas temperature and

Flue - gas stack - Wikipedia
A flue - gas stack is a type of chimney , a vertical pipe, channel or similar structure through which Most 18th-century industrial chimneys (now commonly referred to as flue gas stacks) were built into the walls of h: height of the flue gas stack, in m; To: absolute outside air temperature , in K; Ti: absolute average temperature

Steam and high temperature hot water boilers - Carbon Trust
of flue - gas losses + radiation and other unaccounted losses). 7. Steam and high temperature hot water boilers . Types of fuel used in boilers . There are a wide

Temperature of flue gas out of stack (heat and mass transfer
Enthalpy of air at atm temp and pressure, h3= 298.59775 kJ/kgK. Enthalpy of flue gas What is the temperature of flue gas going out of the chimney ? Flue gases . How can I determine the mass flow rate of steam through a boiler ? Question.