1-20 ton gas/oil fired boiler
Capacity: 1-20 ton/h
Pressure: 0.7-2 Mpa
Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.
Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.
7-70 MW gas/oil fired hot water boiler
Capacity: 7-70 MW
Pressure: 1.0-1.6 Mpa
Fuel: Nature gas, coke oven gas, blast furnace gas, carbon black off-gas, biogas, methanol, LPG, diesel, heavy oil, light oil, crude oil, etc.
Industries: Heat supplying, hospital, colleges and universities.
2.8-29mw coal fired boiler
Capacity: 2.8-29mw
Pressure: 1.0-1.25 Mpa
Fuel: Bituminous coal, lean coal, anthracite
Industries: Heating, hotels, schools, hospitals
horizontal thermal fluid heater
Capacity: 700 - 14000 kw
Pressure: 0.8 - 1.0 Mpa
Fuel: natural gas, coke oven gas, bio-gas,liquid propane gas, diesel, heavy oil, light oil, crude oil
Industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industries
1-20 ton biomass fired boiler
Capacity: 1-20 ton/h
Pressure: 0.7-2.5 Mpa
Fuel: Biomass particles
Industries: Heating, chemical, food, tobacco, textile, printing and dyeing, feed, medicine, building material, wine, rubber, hospital

The Difference between Wetback and Dryback Boilers - The Boiling
16 May 2016 On today's episode of The Boiling Point, Gerald and Ritchie address a topic that WARE gets a lot of questions aboutthe difference between wetback and dryback boilers . Shady Ghazy For Learn Engineering 78,265 views. Learjet 35A Teterboro Runway 1 Approach Crash.

Wetback vs Dryback firetube boiler design
Firetube boilers are available in either dryback or wetback design . They are identified by the type of reversal (turnaround) chamber, or posterior portion of the

What is the difference between dryback boiler design and wetback
7 Oct 2016 There is a reversal chamber for flue gases between 1st & 2nd pass is provided inside the boiler shell .In dryback boiler rear wall is lined with

Wetback and Dryback Boilers Compared | Lathrop Trotter | Lathrop
There are two primary Firetube boiler designs : wetback and dryback. The basic difference between a wetback boiler and a dryback boiler is in the rear wall

Wetback vs Dryback - Burnham Commercial
Wetback vs Dryback. Scotch Marine Boiler Design . 2. Wetback vs Dryback. Goal The purpose of this presentation is to provide project decision-makers with

wet -dry layout - Burnham Commercial
As indicated in the drawing, a three-pass wetback design fact of the matter is a wetback design boiler not only overcomes these expensive deficiencies, but it

Why Our Boilers Are Designed As Wet - Back Boilers : Dry- Back Boiler
13 May 2016 In general, our boilers, like the WNS gas and oil fired boiler, are designed as wet - back structure. Disadvantages of Dry- back boilers . Dry back

wet - back /dry- back firetubes - B.J. Muirhead
Our Model 4WI wet - back firetube boiler not only offers high efficiency but low CBLE firetube boiler has the same design elements of the 4WI only in a dry- back

Powermaster » Wet - Back
Wet - Back . The weakest part of a conventional fire tube boiler is found in the from their boiler designs over 80 years ago and also developed a simpler back lid.

Wet Back Boiler - Hydro Supply
It is far better to spend money and buy an efficient and well- designed boiler than suffer The two most commonly types of boilers are the dry and wet back .

Scotch marine boiler - Wikipedia
The typical design is the " wet back ", where the rear face of Although the Scotch boiler is nowadays rarely the

Firetube Boiler Design and Engineering - Cleaver-Brooks
1 Nov 2015 A wetback firetube boiler has a water-leg located between the turnaround plate and the rear tube sheet. This design element eliminates the

Two Pass Scotch Marine Design with Wetback - Hurst Boiler
HIGH PRESSURE BOILER with capacities from 20 to 2500 BHP. 670 to 83688 MBTU/HR. Up to 86250 PPH Steam. 2-pass scotch marine design with wetback

What is a wetback ? When should you use it in building design
22 Jan 2019 Designing homes to conserve energy and use it efficiently, from sources Some burners can pass the efficiency test without a wetback but fail

wet back steam boiler - WUXI ZOZEN BOILERS CO.,LTD
Firetube boilers are available in either dryback or wetback design . cons of wetback and dryback firetube boilers , contact our steam plant experts at IB&M today.

fire tube 3 pass wet back boiler - WUXI ZOZEN BOILERS CO.,LTD
A "Scotch" marine boiler (or simply Scotch boiler) is a design of steam boiler best known for its use on ships. Sectional diagram of a " wet back " boiler The Scotch

Wetback vs. Dryback Firetube Boiler | CTI Controltech Industrial
4 Oct 2016 Differing boiler designs will provide their own array of positive attributes with regard to boiler efficiency, intended use, maintenance burden, and

Fully Wet Back Boiler - View Specifications & Details of Back Boiler
With a focus on the ever-evolving demands of our customers, we have come up with a wide range of perfectly designed Fully Wet Back Boiler . Our talented

Industrial Boiler FAQs | Superior Boiler
A dryback boiler has a rear wall that is lined with refractory, a wetback boiler has a rear wall that is jacketed by water. Because of this fact, wetback boilers